Chapter 4: Functional Description 4–37
Logical Layer Interfaces
August 2014 Altera Corporation RapidIO II MegaCore Function
User Guide
Port-Write Transmission
To send a RapidIO
MAINTENANCE
port-write packet to a remote device, you must
program the transmit port-write control and data registers. The
Tx Port
Write
Control
register is described in Table 6–45 on page 6–36 and the
Tx
Port
Write
Buffer
is described in Table 6–47 on page 6–37. You access these registers using the Register
Access Avalon-MM slave interface. You must program the values for the following
header fields in the corresponding fields in the
Tx
Port
Write
Control
register:
■
DESTINATION_ID
■
priority
■
wrsize
The RapidIO II IP core assigns the following values to the fields of the
MAINTENANCE
port-write
packet:
■ Assigns
ftype
the value of
4'b1000
■ Assigns
ttype
the value of
4'b0100
■ Calculates the values for the
wdptr
and
wrsize
fields of the transmitted packet
from the size of the
payload
to be sent, as defined by the
size
field of the
Tx
Port
Write
Control
register
■ Assigns the value of 0 to the Reserved
source_tid
and
config_offset
fields
The IP core creates the packet’s
payload
from the contents of the
Tx
Port
Write
Buffer
sequence of registers starting at register address
0x10210
. This buffer can store a
maximum of 64 bytes. The IP core starts the packet composition and transmission
process after you set the
PACKET_READY
bit in the
Tx
Port
Write
Control
register. The
RapidIO II IP core composes the
Maintenance port-write
packet and transmits it on
the RapidIO link.
Port-Write Reception
When the RapidIO II IP core Maintenance module receives a
MAINTENANCE
port-write
request packet (
ftype
has the value of 4’b1000 and
ttype
has the value of 4’b0100)
from the Transport layer, it extracts information from the packet header and uses the
information to write to registers
Rx
Port
Write
Control
(Table 6–48 on page 6–37)
through
Rx
Port
Write
Buffer
(Table 6–50 on page 6–37). The Maintenance module
extracts information from the following fields:
■
wrsize
— the values in the w
rsize
and
wdptr
packet fields determine the value of
the
PAYLOAD_SIZE
field in the
Rx Port Write Status
register (Table 6–49 on
page 6–37).
■
wdptr
— the values in the w
rsize
and
wdptr
packet fields determine the value of
the
PAYLOAD_SIZE
field in the
Rx Port Write Status
register (Table 6–49 on
page 6–37).
■
payload
— the Maintenance module copies the value of the
payload
packet field to
the
Rx
Port
Write Buffer
starting at register address
0x10260
. This buffer holds a
maximum of 64 bytes.
While the IP core is writing the
payload
to the buffer, it holds the
PORT_WRITE_BUSY
bit
of the
Rx
Port
Write
Status
register asserted. After the
payload
is completely written
to the buffer, if you have set the
RX_PACKET_STORED
bit of the
Maintenance Interrupt
Enable
register (Table 6–40 on page 6–35), the IP core asserts the interrupt signal