6–32 Chapter 6: Software Interface
Transport and Logical Layer Registers
RapidIO II MegaCore Function August 2014 Altera Corporation
User Guide
Command and Status Registers (CSRs)
Table 6–32 through Table 6–38 describe the command and status registers.
Table 6–32. Data Streaming Logical Layer Control CSR—Offset: 0x48
Field Bits Access Function Default
TM_TYPE_SUPPORT
[31:28] RO
TM types supported. This field indicates the TM types that the
RapidIO II IP core variation supports.
The following values are valid:
4'b1000: Supports basic type
4’b1100: Supports basic and rate types
4’b1010: Supports basic and credit types
4’b1110: Supports basic, rate, and credit types
All other values are invalid.
(2)
TM_MODE
(1)
[27:24] RW
Traffic management mode. The following values are valid:
4'b0000: TM disabled
4’b0001: Basic mode
4’b0010: Rate mode
4’b0011: Credit mode
4’b0101–4’b0111: Reserved
4’b1000–4’b1111: Available for user-defined modes
(2)
RSRV
[23:8] RO Reserved 29'h0
MTU
(1)
[7:0] RW
Maximum transmission unit. This field controls the data payload size
for segments of an encapsulated PDU. All segments of a PDU except
the final segment must have a data payload of the length specified in
this field. The MTU is a multiple of four bytes.
The following values are valid:
8'b0000_1000: 32-byte block size
8’b0000_1001: 64-byte block size
8’b0000_1010: 40-byte block size
...
8’b0100_0000: 256-byte block size
The following values are invalid:
8’b0000_0000–8’b0000_0111: Reserved
8’b0100_0001–8’b1111_1111: Reserved
(2)
Notes to Table 6–32:
(1) To change the value of this field dynamically during normal operation, use the corresponding
_wr
and
_in
signals to control the timing of the
value changes.
(2) The reset value is set in the RapidIO II parameter editor.