6–18 Chapter 6: Software Interface
Physical Layer Registers
RapidIO II MegaCore Function August 2014 Altera Corporation
User Guide
PORT_DIS
[23] RW
Port disable:
'b0—Port receivers/drivers are enabled.
'b1—Port receivers are disabled and are unable to receive or
transmit any packets or control symbols.
While this bit is set, the initialization state machines’
force_reinit
signal is asserted. This assertion forces the port to the SILENT state
1'b0
OUT_PENA
[22] RW
Output port transmit enable:
'b0—Port is stopped and not enabled to issue any packets except
to route or respond to I/O logical
MAINTENANCE
packets. Control
symbols are not affected and are sent normally.
'b1—Port is enabled to issue packets.
The value in the
PORT_LOCKOUT
field (bit [1] of this register) can
override the values in the
OUT_PENA
and
IN_PENA
fields
1'b0
IN_PENA
[21] RW
Input port receive enable:
'b0—Port is stopped and only enabled to respond to I/O Logical
MAINTENANCE
requests. Other requests return
packet-not-
accepted
control symbols to force an error condition to be
signaled by the sending device. However, the IP core still handles
normally any control symbols it receives.
'b1—Port is enabled to respond to any packet.
The value in the
PORT_LOCKOUT
field (bit [1] of this register) can
override the values in the
OUT_PENA
and
IN_PENA
fields.
1'b0
ERR_CHK_DIS
[20] RO
This bit enables (1’b0) or disables (1’b1) all RapidIO transmission
error checking. The RapidIO II IP core does not support the
disabling of error checking and recovery, so this bit always has the
value of 1’b0.
1'b0
Multicast-event
Participant
[19] RW
Indicates that the system should send incoming Multicast-event
control symbols to this port (multiple port devices only).
1'b1
Flow Control
Participant
[18] RW
Enables or disables flow control transactions:
1’b0: Do not route or issue flow control transactions to this port
1’b1: Route or issue flow control transactions to this port.
This field does not affect the IP core configuration.
(1)
Enumeration
Boundary
[17] RW
Indicates whether this port should delimit enumeration. Any
enumeration boundary aware system enumeration algorithm should
honor this flag. The algorithm, on either the Rx port or the Tx port,
should not enumerate past a port in which this bit is set to the value
of 1’b1. This field supports software-enforced enumeration domains
in the RapidIO network.
(1)
Flow Arbitration
Participant
[16] RW
Enables or disables flow arbitration transactions:
1’b0: Do not route or issue flow arbitration transactions to this
port
1’b1: Route or issue flow arbitration transactions to this port.
(1)
Table 6–15. Port 0 Control CSR—Offset: 0x15C (Part 2 of 4)
Field Bits Access Function Default