Chapter 6: Software Interface 6–55
Transport and Logical Layer Registers
August 2014 Altera Corporation RapidIO II MegaCore Function
User Guide
INFORMATION
[7:0] RO
LSB of the information field of an outbound
DOORBELL
message that has been confirmed as successful or
unsuccessful.
8'h0
Note to Table 6–89:
(1) The completed Tx
DOORBELL
message comes directly from the Tx Doorbell Completion FIFO.
Table 6–89. Tx Doorbell Completion—Offset: 0x14
(1)
(Part 2 of 2)
Field Bits Access Function Default
Table 6–90. Tx Doorbell Completion Status—Offset: 0x18
Field Bits Access Function Default
RSRV
[31:2] RO Reserved
30'h0
ERROR_CODE
[1:0] RO
This error code corresponds to the most recently read message from
the
Tx
Doorbell
Completion
register. After software reads the
Tx
Doorbell
Completion
register, a read to this register should follow
to determine the status of the message.
2'b00—Response
DONE
status
2'b01—Response with
ERROR
status
2'b10—Time-out error
2'h0
Table 6–91. Tx Doorbell Status Control—Offset: 0x1C
Field Bits Access Function Default
RSRV
[31:2] RO Reserved
30'h0
ERROR
[1] RW
If set, outbound
DOORBELL
messages that received a response with
ERROR
status, or were timed out, are stored in the Tx Completion
FIFO. Otherwise, no error reporting occurs.
1'h0
COMPLETED
[0] RW
If set, responses to successful outbound
DOORBELL
messages are
stored in the Tx Completion FIFO. Otherwise, these responses are
discarded.
1'h0
Table 6–92. Doorbell Interrupt Enable—Offset: 0x20
Field Bits Access Function Default
RSRV
[31:3] RO Reserved
29'b0
TX_CPL_OVERFLOW
[2] RW Tx Doorbell Completion Buffer Overflow Interrupt Enable
1'h0
TX_CPL
[1] RW Tx Doorbell Completion Interrupt Enable
1'h0
RX
[0] RW Doorbell Received Interrupt Enable
1'h0
Table 6–93. Doorbell Interrupt Status—Offset: 0x24 (Part 1 of 2)
Field Bits Access Function Default
RSRV
[31:3] RO Reserved
29'h0
TX_CPL_OVERFLOW
[2] RW1C
Interrupt asserted due to Tx Completion buffer overflow. This bit
remains set until at least one entry is read from the Tx
Completion FIFO. After reading at least one entry, software
should clear this bit. It is not necessary to read all of the Tx
Completion FIFO entries.
1'h0
Comentarios a estos manuales