Additional Information Info–3
Document Revision History
August 2014 Altera Corporation RapidIO II MegaCore Function
User Guide
June 2014,
continued
Continued on
next page
14.0
Corrected descriptions of
IN_ERR_STOP
and
OUT_ERR_STOP
fields of the
Port 0 Error
and Status CSR
(offset 0x158, Table 6–14 on page 6–12) to state that the three control
symbols unexpected
packet-accepted
, unexpected
packet-retry
, and unexpected
packet-not-accepted
, set the
OUT_ERR_STOP
bit (and take the state machine into the
corresponding state) and not the
IN_ERR_STOP
bit as was previously indicated.
Replaced “Serial RapidIO” with “RapidIO”. The RapidIO II IP core supports only the Serial
RapidIO specification.
Clarified in Table 5–6 on page 5–4 that the user must implement the logic to utilize the
link_req_reset_device_received
output signal to reset the IP core.
Fixed descriptions of
OUTBOUND_ACKID
and
OUTSTANDING_ACKID
fields of the
Port 0
Local AckID CSR
(0x148 , Table 6–12 on page 6–10). The user cannot write directly to
the
OUTSTANDING_ACKID
field. Instead, if software writes to the
OUTBOUND_ACKID
field,
the new value appears in both the
OUTBOUND_ACKID
field and the
OUTSTANDING_ACKID
field. The user can write to
OUTBOUND_ACKID
to force retransmission of outstanding
unacknowledged packets,
Corrected erroneous statement that software can reset the
REMOTE_TX_EMPH_ENABLE
bit
in the
Port 0 Control 2 CSR
(offset 0x154, Table 6–13 on page 6–10). This bit cannot
be reset, and remote transmit emphasis control is always turned on.
Corrected description of
PORT_ERR
field of Port 0 Error and Status CSR (offset 0x158,
Table 6–14 on page 6–12) and list of events that cause stored packets to be lost (in
“Low-Level Interface Transmitter” on page 4–75): removed erroneous indication that
port_status
value of Error can lead to a fatal error. The IP core has no specific reaction
to
port_status
being set to Error. Instead, the user can identify this situation from the
Port 0 Link Maintenance Response
CSR’s
PORT_STATUS
field, and handle it in
software.
Added new information to the description of the
Logical/Transport Layer Address
Capture CSR
(offset 0x314, Table 6–69 on page 6–47): in the case of a
MAINTENANCE
Response with Error status, the
ADDRESS
field now captures the
config_offset
value
from the original request.
Clarified in “Clocking and Reset Structure” on page 4–3 that the transceiver reference
clock (
tx_pll_refclk)
and the system clock (
sys_clk
) inputs must be generated from
the same clock source.
Clarified in Appendix B, Differences Between RapidIO II MegaCore Function v12.1 and
RapidIO MegaCore Function v12.1:
In the RapidIO II IP core, you cannot independently select whether or not to support
port-write
transactions. If you include a Maintenance module in your design, your
IP core supports
port-write
transactions.
In the RapidIO II IP core (in contrast to the RapidIO IP core) on the Avalon-ST pass-
through interface in the RX direction only, the sourceID and destinationID fields in
gen_rx_hd_data
are 16 bits wide even if the device ID width for the IP core variation
is 8 bits. However, in the TX direction, as in the RapidIO IP core, the sourceID and
destinationID field width depends on the device ID width.
Since v13.0, RapidIO IP core has 2x variations, which has same Avalon-MM I/O
Logical layer data bus width as the 4x variations.
In Sending Link-Request Reset-Device on Fatal Errors parameter entry, added
information for full comparison.
Corrected descriptions of Port 0 Packet Capture 1-3 CSRs to no longer erroneously
indicate their values are affected when the
Port 0 Attributes Capture
CSR
INFO_TYPE
field value is Long control symbol.