Signal Name Direction Description
rx_parallel_data<n>
[70]
Output
When asserted, indicates that the RX frame synchronization
state machine has found and received 4 consecutive, valid
synchronization words. The frame synchronization state
machine requires 4 consecutive synchronization words to exit
the presync state and enter the synchronized state. You should
only use this optional signal as a secondary status flag. The rx_
parallel_data[66] signal should be used as the primary
frame synchronization status flag. This output is synchronous
to the rx_clkout clock domain.
This signal is optional. If the RX PCS FIFO reaches an empty
state or is in an empty state, rx_parallel_data<n>[70]
indicating metaframe lock and rx_parallel_data<n>[69]
indicating that the first Interlaken synchronization word
alignment pattern has been received remain asserted but rx_
parallel_data<n>[66] block lock and frame lock status signal
are deasserted in the next clock cycle.
rx_parallel_data<n>
[71]
Output When asserted, indicates a CRC32 error in this lane. This signal
is optional. This output is synchronous to the rx_clkout clock
domain.
rx_ready Output When asserted, indicates that the RX interface has exited the
reset state and is ready for service. The Interlaken MAC must
wait for rx_ready to be asserted before initiating data transfer
on any lanes. This output is synchronous to the phy_mgmt_clk
domain.
rx_clkout Output Output clock from the RX PCS. The frequency of this clock
equals the Lane rate divided by 40, which is the PMA serializa‐
tion factor.
rx_fifo_clr<n> Input
When asserted, the RX FIFO is flushed. This signal allows you
to clear the FIFO if the receive FIFO overflows or if the
Interlaken MAC is not able to achieve multi-lane alignment in
the Interlaken MAC's deskew state machine. The rx_fifo_clr
signal must be asserted for 4 rx_clkout cycles to successfully
flush the RX FIFO.
This output is synchronous to the rx_clkout clock domain.
UG-01080
2015.01.19
Interlaken PHY Avalon-ST RX Interface
7-13
Interlaken PHY IP Core
Altera Corporation
Send Feedback