Parameter Type Description
use_no_phase_shift String When set to OFF, a phase shift of 90° is added to the
clock to center the clock in the data. Use this
parameter when the implement_in_les parameter
value is set to ON for Cyclone II, Stratix II, Stratix III,
and Stratix IV devices. The values are ON and OFF. If
omitted, default value is ON. Altera recommends
setting this parameter to OFF unless you have
completed a phase adjustment.
The following table lists the DESERIALIZATION_FACTOR and outclock_divide_by values.
Table 8: DESERIALIZATION_FACTOR and OUTCLOCK_DIVIDE_BY Values
Devices DESERIALIZATION_FACTOR
Value
OUTCLOCK_DIVIDE_BY Value
Arria GX, Arria II GX,
Arria II GZ, Arria V, Arria
V GZ, HardCopy II,
HardCopy III, HardCopy
IV, Stratix II, Stratix II GX,
Stratix III, Stratix IV, and
Stratix V
4
2
4
5 5
6
2
6
7 7
8
2
4
8
9 9
10
2
10
Stratix and Stratix GX
4
2
4
7 7
8
2
4
8
10
2
10
32