Altera Stratix V Avalon-ST Manual de usuario Pagina 124

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 158
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 123
Figure 8-2: Correctable Error Status Register
The default value of all the bits of this register is 0. An error status bit that is set indicates that the error
condition it represents has been detected. Software may clear the error status by writing a 1 to the
appropriate bit.
Rsvd
Rsvd Rsvd
Header Log Overflow Status
Corrected Internal Error Status
Advisory Non-Fatal Error Status
Replay Timer Timeout Status
REPLAY_NUM Rollover Status
Bad DLLP Status
Bad TLP Status
Receiver Error Status
16 15 14 13 12
11 9 8 7 6 5
1 0
31
UG-01097_sriov
2014.12.15
Uncorrectable and Correctable Error Status Bits
8-7
Error Handling
Altera Corporation
Send Feedback
Vista de pagina 123
1 2 ... 119 120 121 122 123 124 125 126 127 128 129 ... 157 158

Comentarios a estos manuales

Sin comentarios