Output Read Data in Simultaneous Read and Write
If you perform a simultaneous read/write to the same address location using the read or write clock mode,
the output read data is unknown. If you want the output read data to be a known value, use single-clock
or input/output clock mode and then select the appropriate read-during-write behavior in the RAM: 1-
PORT and RAM: 2-PORT IP cores.
Related Information
MAX 10 Embedded Memory Clock Modes on page 2-9
Independent Clock Enables in Clock Modes
Table 2-3: Supported Clock Modes for Independent Clock Enables
Clock Mode Description
Read/write Supported for both the read and write clocks.
Independent Supported for the registers of both ports.
MAX 10 Embedded Memory Configurations
Table 2-4: Maximum Configurations Supported for M9K Embedded Memory Blocks
Feature M9K Block
Configurations (depth × width)
8192 × 1
4096 × 2
2048 × 4
1024 × 8
1024 × 9
512 × 16
512 × 18
256 × 32
256 × 36
Port Width Configurations
The following equation defines the port width configuration: Memory depth (number of words) × Width
of the data input bus.
2-10