Table 15-4: ALTFP_ABS Output Signals
Port Name Required Description
result[] Yes The absolute value result of the input data. The size of this
port corresponds to the size of the input data[] port.
zero No Zero exception output carried from the input. Asserted if the
corresponding carry-through port from the input is asserted.
nan No NaN output carried from the input. Asserted if the
corresponding carry-through port from the input is asserted.
overflow No Overflow exception output carried from the input. Asserted
if the corresponding carry-through port from the input is
asserted.
underflow No Underflow exception output carried from the input. Asserted
if the corresponding carry-through port from the input is
asserted.
division_by_zero No Division-by-zero exception output carried from the input.
Asserted if the corresponding carry-through port from the
input is asserted.
ALTFP_ABS Parameters
Table 15-5: ALTFP_ABS Parameters
Port Name Type Required Description
WIDTH_EXP Integer Yes Specifies the precision of the exponent. If this
parameter is not specified, the default is 8. The
bias of the exponent is always set to 2 (WIDTH_
EXP - 1) - 1, that is, 127 for the single-precision
format and 1023 for the double-precision
format. The value of WIDTH_EXP must be 8 for
the single-precision format, 11 for the double-
precision format, and a minimum of 11 for the
single-extended precision format. The value of
WIDTH_EXP must be less than the value of WIDTH_
MAN, and the sum of WIDTH_EXP and WIDTH_MAN
must be less than 64.
UG-01058
2014.12.19
ALTFP_ABS Parameters
15-5
ALTFP_ABS IP Core
Altera Corporation
Send Feedback