10.From the Simulation list, select ModelSim
®
. From the Format list, select the HDL language you
intend to use for simulation.
11.Click Next to display the Summary page.
12.Check the Summary page to ensure that you have entered all the information correctly.
13.Click Finish to create the Quartus II project.
14.Before compiling, you must assign I/O standards to the pins of the device. Refer to Making Pin
Assignments to Assign I/O Standard to Serial Data Pins for instructions.
15.You must connect the pin_perst reset signal to the correcsponding nPERST pin of the device. Refer to
the definition of pin_perst in the Reset, Status, and Link Training Signals section for more informa‐
tion.
16.Next, set the value of the test_in bus to a value that is compatible for hardware testing. In Qsys design
example provided, test_in is a top-level port.
a. Comment out the test_in port in the top-level Verilog generated file.
b. Add the following declaration, wire[31:0] test_in, to the same top-level Verilog file.
c. Assign hip_ctrl_test_in = 32'hA8.
d. Connect test_in to hip_ctrl_test_in.
Refer to the definition of test_in in the Test Signals section for more information about the bits of the
test_in bus.
17.Add the Synopsys Design Constraint (SDC) shown in the following example below to the top-level
design file for your Quartus II project.
18.To compile your design using the Quartus II software, on the Processing menu, click Start Compila‐
tion. The Quartus II software then performs all the steps necessary to compile your design.
Example 2-1: Synopsys Design Constraints
create_clock -period “100 MHz” -name {refclk_pci_express}{*refclk_*}
derive_pll_clocks
derive_clock_uncertainty
# PHY IP reconfig controller constraints
# Set reconfig_xcvr clock
# Modify to match the actual clock pin name
# used for this clock, and also changed to have the correct period set
create_clock -period "125 MHz" -name {reconfig_xcvr_clk}{*reconfig_xcvr_clk*}
# HIP Soft reset controller SDC constraints
set_false_path -to [get_registers* altpcie_rs_serdes|fifo_err_sync_r[0]]
set_false_path -from [get_registers *sv_xcvr_pipe_native*] -to[get_registers
*altpcie_rs_serdes|*]
# Hard IP testin pins SDC constraints
set_false_path -from [get_pins -compatibilitly_mode *hip_ctrl*]