5–22 Chapter 5: Functional Description—Transmitter
Signals
POS-PHY Level 4 IP Core User Guide December 2014 Altera Corporation
Table 5–8. Data Path and Control Status (Part 1 of 2)
Signal Direction Clock Domain Description
ctl_td_holb_disable
Input- Static
reset
tdint_clk
Head-of-line blocking disable. When set to logic 1,
the data path requests data from the scheduler or
Atlantic buffer(s) whenever possible. When set to
logic 0, status (after error checking) is monitored for
all ports, and while any port is satisfied, the
transmitter stops requesting data from the scheduler
or Atlantic buffer(s), and sends idle control words or
training patterns. This input is tied to one in the IP
Toolbench top-level file, if you use the individual
buffers mode. Only change at reset.
stat_td_holb
Output
Indicates if the IP core is currently head-of-line
blocked. It is never asserted if
ctl_td_holb_disable
is set to logic 1.
ctl_td_maxt[15:0]
Input
Training sequence interval, measured from the end of
the last training sequence to the beginning of the next
training sequence. The actual interval may be slightly
longer to maintain valid bursts according to
ctl_td_burstlen
. Setting to zero disables interval
training insertion. Training is always inserted if
stat_ts_sync
is deasserted. Training patterns
always begin on the positive edge of
tdclk
. Only
change at reset.