Mentor VIP AE AXI3/4 User Guide, V10.2b
542
VHDL AXI3 and AXI4 Monitor BFMs
get_gen_write_strobes()
September 2013
AXI4 Example
-- Create a monitor transaction. Creation returns tr_id to identify the
transaction.
create_monitor_transaction(tr_id, bfm_index, axi4_tr_if_0(bfm_index));
....
-- Get the auto correction write strobes flag of the tr_id transaction.
get_gen_write_strobes(write_strobes_flag, tr_id, bfm_index,
axi4_tr_if_0(bfm_index));