Page 10 Functional Description
Multiaxis Motor Control Board February 2014 Altera Corporation
The following equation calculates the current in the third, V, phase:
I
v
= –I
u
–I
w
ADC Clock Tree
The 20-MHz ADC sample clock from the HSMC connector,
CLK_HSMC_ADC
, is buffered
by a tree of CDCLVC1106 low-skew clock buffers (Figure 6).
To compensate for the isolator device propagation delays, the HSMC connector
provides a feedback clock,
CLK_HSMC_FEEDBACK
, to the FPGA. The Multiaxis Motor
Control Board compensates for the isolator propagation delays, but you must still
account for the part-to-part skew when creating I/O timing constraints for the FPGA
design.
Alternatively, you can use a PLL in the FPGA to create a phase shifted version of the
ADC clock for sampling the inputs.
Figure 6. Clock Tree
TI CDCLVC116
1:6 Buffers
Motor
Channel 0
ADCs
Total Current
& DC Link
ADCs
ADC
ADC Data
Feedback Clock
Isolator
HSMC
Connector
Motor
Channel 1
ADCs
Motor
Channel 2
ADCs
Motor
Channel 3
ADCs