Figure 44:
The following set_false_path commands ensure that we are analyzing only the same edge
transfers, by removing the opposite edge transfers.
Note:
These assignments are optional.
Example 5: set_false_path Commands
set_false_path -setup -rise_from [get_clocks{pll_inst/alterapll_inst/
altera_pll_i/general[2].gpllPLL_OUTPUT_COUNTER/divclk}] -fall_to
[get_clocks{dqs_out}]
set_false_path -setup -fall_from [get_clocks{pll_inst/alterapll_inst/
altera_pll_i/general[2].gpllPLL_OUTPUT_COUNTER/divclk}] -rise_to
[get_clocks{dqs_out}]
set_false_path -hold -rise_from [get_clocks{pll_inst/alterapll_inst/
altera_pll_i/general[2].gpllPLL_OUTPUT_COUNTER/divclk}] -rise_to
[get_clocks{dqs_out}]
set_false_path -hold -fall_from [get_clocks{pll_inst/alterapll_inst/
altera_pll_i/general[2].gpllPLL_OUTPUT_COUNTER/divclk}] -fall_to
[get_clocks{dqs_out}]
The following set_multicycle_path commands ensure that the correct transfer between the DDlO and
Read FlFO.
Example 6: set_multicycle_path Commands
set_multicycle_path -from {*/altdq_dqs2_stratixv:altdq_dqs2_inst/
input_path_gen[*].capture_regHIGH_DFF} -to {*/
76