3–6 Chapter 3: Parameter Settings
Specifying the Coefficients
FIR Compiler User Guide © May 2011 Altera Corporation
Loading Coefficients from a File
To load a coefficient set from a file, perform the following steps:
1. Click New Coefficient Set in the Parameterize - FIR Compiler page (Figure 3–1
on page 3–2); then select Imported Coefficient Set in the Coefficients Generator
dialog box (Figure 3–6 on page 3–7).
Figure 3–5. IP Toolbench Parameterize Page, Time Response and Coefficient Values Tab