Chapter 5: Board Test System 5–11
Using the Board Test System
June 2014 Altera Corporation Arria V SoC Development Kit
User Guide
bits—Displays the number of bits transmitted since clicking Start.
Inserted errors—Displays the number of errors inserted by clicking Insert Error
button.
Detected errors—Displays the number of bit errors detected by the error checking
circuitry.
BER—Displays the bit error rate of the interface.
PLL lock—Displays Yes if the SDI PLL is locked.
Pattern sync—Displays Yes if the receiver has detected the input data pattern.
Start— Starts the PRBS data test and begins to monitor and update screen with
live test results.
Stop—Stops the PRBS data test.
Insert Error—Inserts an error into a data stream that is detected by the receiver
when in loopback using the included video cable.
With the Insert Error, there are differences among the three ports:
SFP A—Inserts 4 errors at 1 click due to 4 test blocks control.
SFP B—Inserts 3 errors at 1 click due to 3 test blocks control.
SMA—Inserts 1 error at 1 click.
Clear—Clears the Detected errors counter.
PMA Setting—Opens the PMA settings window that allows for adjusting the
analog transceiver settings, such as output voltage, loopback settings, and
equalization.
The following settings are available for analysis:
Serial LoopbackRoutes the selected TX output signal back to the RX input
signal on-chip to verify operation without using an external loopback board.
VOD—Specifies the voltage output differential of the transmitter buffer.
Pre-emphasis tap
Pre—Specifies the amount of pre-emphasis on the pre-tap of the transmitter
buffer.
First post—Specifies the amount of pre-emphasis on the first post tap of the
transmitter buffer.
Second post—Specifies the amount of pre-emphasis on the second post tap
of the transmitter buffer.
Equalizer—Specifies the setting for the receiver equalizer.
DC gain—Specifies the DC portion of the receiver equalizer.
PRBS—Selects the transmit pattern and sets the receive error detection
circuitry to expect the same pattern for use in loopback testing.