Signal Direction Description
status_update_int Output control slave port Avalon-MM interrupt signal. When
asserted, the status registers of the IP core have been
updated and the master must read them to determine
what has occurred.
Note: Present only if you turn on Use control port.
vid_clk Input Clocked video clock. All the video output signals are
synchronous to this clock.
vid_data Output Clocked video data bus. This bus transfers video data into
the IP core.
vid_datavalid Output Clocked video data valid signal. Assert this signal when a
valid sample of video data is present on vid_data.
vid_f Output Clocked video field signal. For interlaced input, this signal
distinguishes between field 0 and field 1. For progressive
video, this signal is unused.
Note: For separate synchronization mode only.
vid_h Output Clocked video horizontal blanking signal. This signal is
asserted during the horizontal blanking period of the
video stream.
Note: For separate synchronization mode only.
vid_h_sync Output Clocked video horizontal synchronization signal. This
signal is asserted during the horizontal synchronization
period of the video stream.
Note: For separate synchronization mode only.
vid_ln Output Clocked video line number signal. Used with the SDI IP
core to indicate the current line number when the vid_
trs signal is asserted.
Note: For embedded synchronization mode only.
vid_mode_change Output Clocked video mode change signal. This signal is asserted
on the cycle before a mode change occurs.
vid_sof Output Start of frame signal. A rising edge (0 to 1) indicates the
start of the video frame as configured by the SOF registers.
vid_sof_locked Output Start of frame locked signal. When asserted, the vid_sof
signal is valid and can be used.
vid_std Output Video standard bus. Can be connected to the tx_std
signal of the SDI IP core (or any other interface) to read
from the Standard register.