26 Altera Corporation
SerialLite II Protocol Reference Manual
Physical Layer Description
Training Sequence One Ordered Set Sequence {|TS1|}
The first link training sequence consists of eight ordered sets as shown in
Table 2–13. This sequence is used to initialize the links.
Training Sequence Two Ordered Set Sequence {|TS2|}
The second link training sequence consists of eight ordered sets as shown
in Table 2–14. This sequence is used to indicate that link initialization is
complete, and forms part of the link-deskew sequence.
Table 2–13. {|TS1|} Composition
Field Ordered Set Description
TC ||COM|| Comma (or Sync) identifier
LN ||DAT|| Lane number. A number from 0 to 255 (in
8-bit space, encoded before transmission,
with 0 representing the most significant
lane)
MLN ||DAT|| Maximum lane number. A number from 0 to
255 (in 8-bit space, encoded before
transmission, with 0 representing a single
lane implementation)
TSZ ||DAT|| Transfer size. Valid numbers are 1, 2, and
4. The transfer size defines the number of
columns for a contiguous burst of data; 1
column, 2 columns, 4 columns, and all
other values are reserved.
RSV 3x||DAT|| Reserved. Set to all zeros (D0.0); repeated
three times
T1 ||DAT|| First training sequence identifier (D10.2)
Table 2–14. {|TS2|} Composition
Field Ordered Set Description
TC ||COM|| Comma (or Sync) identifier
LN ||DAT|| Lane number. A number from 0 to 255 (in
8-bit space, encoded before transmission,
with 0 representing the most significant
lane)
MLN ||DAT|| Maximum lane number. A number from 0 to
255 (in 8-bit space, encoded before
transmission, with 0 representing a single
lane implementation)