Figure 5-42: Layout of Power Management Capabilities Register
data_selectdata_scale PM_statePME_ENPME_status reserved
15 011623 8 2791213142431
reserved
data
register
Table 5-20: Power Management Capabilities Register Field Descriptions
Bits Field Description
[31:24]
Data register
This field indicates in which power states a function can assert
the PME# message.
[23:16]
reserved
[15]
PME_status
When set to 1, indicates that the function would normally assert
the PME# message independently of the state of the PME_en bit.
[14:13]
data_scale
This field indicates the scaling factor when interpreting the value
retrieved from the data register. This field is read-only.
[12:9]
data_select
This field indicates which data should be reported through the
data register and the data_scale field.
[8]
PME_EN
1: indicates that the function can assert PME#0: indicates that the
function cannot assert PME#
[7:2]
reserved
[1:0]
PM_state
Specifies the power management state of the operating condition
being described. The following encodings are defined:
2b’00 D0
2b’01 D1
2b’10 D2
2b’11 D3
A device returns 2b’11 in this field and Aux or PME Aux in the
type register to specify the D3-Cold PM state. An encoding of
2b’11 along with any other type register value specifies the D3-
Hot state.