Page 24 Design Example
Phase-Locked Loop Reconfiguration (ALTPLL_RECONFIG) Megafunction February 2012 Altera Corporation
Parameter Settings
(Scan/Inputs/Lock)
Create an ‘pllena’ input to selectively enable
the PLL
Disabled
Create an ‘areset’ input to asynchronously
reset the PLL
Turned on
Create an ‘pfdena’ input to selectively
enable the phase/frequency detector
Turned off
Create ‘locked’ output Turned on
Enable self reset on loss lock Turned off
Create output file(s) using ‘Advanced’ PLL
parameters
Turned off
PLL Reconfiguration
Create optional inputs for dynamic
reconfiguration
Turned on
Initial Configuration File (filename)
the_pll_initial.mif—taking an
inclock
of
50 MHz and generating
c0
of 100 MHz
Ensure that this option shows the correct path of
the .mif file before compiling the design to avoid
scan chain mismatch warnings.
Additional Configuration File (filename)
The files are already generated. They are:
■ the_pll_200_mhz.mif—taking an
inclock
of
50 MHz and generating
c0
of 200 MHz
■ the_pll_300_mhz.mif—taking an
inclock
of
50 MHz and generating c0 of 300 MHz
■ the_pll_400_mhz.mif—taking an
inclock
of
50 MHz and generating
c0
of 400 MHz
■ the_pll_500_mhz.mif—taking an
inclock
of
50 MHz and generating
c0
of 500 MHz
Create optional inputs for dynamic phase
reconfiguration
Turned off
Output Clocks
(clk c0)
Use this clock Turned on
Enter output clock frequency 100 MHz
Clock phase shift 0 degrees
Clock duty cycle (%) 50
EDA Generate netlist Turned off
Summary
Variation file Turned on
PinPlanner ports PPF file Turned on
AHDL Include file Turned on
VHDL component declaration file Turned on
Quartus II symbol file Turned on
Instantiation template file Turned on
Verilog HDL block box file Turned on
Reconfiguration File for altpll_reconfig Turned on
Table 6. Configuration Settings for the ALTPLL Megafunction (Part 2 of 2)
MegaWizard Plug-In
Manager Page
Settings Value