Port Name Required Description
signa No Specifies the numerical representation of the dataa[] port. If
the signa port is high, the multiplier treats the dataa[] port
as signed two's complement. If the signa port is low, the
multiplier treats the dataa[] port as an unsigned number.
signb No Specifies the numerical representation of the datab[] port. If
the signb port is high, the multiplier treats the datab[] port
as signed two's complement. If the signb port is low, the
multiplier treats the datab[]port as an unsigned number.
Table 5-6: ALTMULT_ACCUM IP Core Output Ports
Port Name Required Description
overflow No Overflow port for the accumulator.
result[] Yes Accumulator output port. The size of the output port depends
on the WIDTH_RESULT parameter value.
scanouta[] No Output of the first shift register. The size of the output port
depends on the WIDTH_A parameter value. When instantiating
the ALTMULT_ACCUM IP core with the MegaWizard Plug-
In Manager, the MegaWizard Plug-In Manager renames the
scanouta[] port to shiftouta port.
scanoutb[] No Output of the second shift register. The size of the input port
depends on the WIDTH_B parameter value. When instantiating
the ALTMULT_ACCUM IP core with the MegaWizard Plug-
In Manager, the MegaWizard Plug-In Manager renames the
scanoutb[] port to shiftoutb port.
UG-M10DSP
2014.09.22
ALTMULT_ACCUM Ports
5-9
ALTMULT_ACCUM (Multiply-Accumulate) IP Core References
Altera Corporation
Send Feedback